dc.description.abstractLos EAHE son sistemas de pre-tratamiento térmico del caudal de aire exterior de ventilación que aprovechan la inercia térmica del terreno, por lo que permiten reducir el consumo energético necesario para alcanzar las condiciones de confort térmico en los espacios acondicionados interiores. Es una tecnología que permite mejorar la eficiencia energética de las Instalaciones Térmicas, reduciendo las emisiones equivalentes de CO2. Así pues, puede ser útil para conseguir los objetivos europeos de reducción de emisiones de CO2. La Universidad de Valladolid ha implantado EAHE en algunos de sus nuevos edificios, entre los que se encuentra el edificio LUCIA. No obstante, actualmente, la información sobre el comportamiento de este tipo de intercambiadores en el clima mediterráneo es escasa, por lo que profundizar en el EAHE de este caso de estudio puede resultar una interesante contribución. El edificio LUCIA cuenta con un SCADA para monitorizar y controlar el funcionamiento de sus instalaciones térmicas, pero los datos que recoge respecto al EAHE no permiten conocer la transferencia de calor. Con el objetivo de conocer su comportamiento y aprovechamiento real se ha efectuado una campaña de mediciones, que complementa la información obtenida del SCADA. Como resultado se obtiene que la implantación del EAHE en el edificio LUCIA supone una reducción del 17% del consumo en calefacción (diciembre, enero y febrero), y del 10% en refrigeración (julio), lo cual supone evitar 665 kg emisiones de CO2, con una inversión de 0,5% del presupuesto de ejecución material del edificio.es
dc.description.abstractThe EAHE are systems for the thermal pre-treatment of the external ventilation air flow that take advantage of the thermal inertia of the ground, thus reducing the energy consumption necessary to achieve the conditions of thermal comfort in the interior conditioned spaces. It is a technology that improves the energy efficiency of Thermal Installations, reducing the equivalent emissions of CO2. Therefore, it can be useful to achieve the European CO2 emission reduction targets. The University of Valladolid has implemented EAHE in some of its new buildings, among which is the LUCIA building. However, currently, information on the behaviour of this type of exchangers in the Mediterranean climate is scarce, so delving into the EAHE of this case study may be an interesting contribution. The LUCIA building has a SCADA to monitor and control the operation of its thermal installations, but the data it collects regarding the EAHE does not allow to know the heat transfer. In order to know its behaviour and real use, a measurement campaign has been carried out to complement the information obtained from the SCADA. As a result, it is obtained that the implementation of the EAHE in the LUCIA building equals to a reduction of 17% of the consumption in heating (December, January and February), and of 10% in cooling (July), which means avoiding 665 kg CO2 emissions, with an investment of 0.5% of the budget for the material execution of the building.es
dc.description.sponsorshipDepartamento de Ingeniería Energética y Fluidomecánicaes
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.classificationIntercambiador de calor Tierra-Airees
dc.subject.classificationAhorro económicoes
dc.subject.classificationReducción de emisiones de CO2es
dc.subject.classificationAprovechamientoes
dc.subject.classificationEdificio Lucíaes
dc.titleAprovechamiento real del intercambiador de calor Tierra-Aire; Caso de estudio: Edificio Lucíaes
dc.typeinfo:eu-repo/semantics/masterThesises
dc.description.degreeMáster en Ingeniería Industriales
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.subject.unesco3305.90 Transmisión de Calor en la Edificaciónes