• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Stöbern

    Gesamter BestandBereicheErscheinungsdatumAutorenSchlagwortenTiteln

    Mein Benutzerkonto

    Einloggen

    Statistik

    Benutzungsstatistik

    Compartir

    Dokumentanzeige 
    •   UVaDOC Startseite
    • WISSENSCHAFTLICHE ARBEITEN
    • Departamentos
    • Dpto. Ingeniería Energética y Fluidomecánica
    • DEP46 - Artículos de revista
    • Dokumentanzeige
    •   UVaDOC Startseite
    • WISSENSCHAFTLICHE ARBEITEN
    • Departamentos
    • Dpto. Ingeniería Energética y Fluidomecánica
    • DEP46 - Artículos de revista
    • Dokumentanzeige
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/55879

    Título
    Improved performance of a PV integrated ventilated façade at an existing nZEB
    Autor
    Tejero González, AnaAutoridad UVA Orcid
    Krawczyk, Dorota Anna
    Rey Martínez, Francisco JavierAutoridad UVA Orcid
    Velasco Gómez, EloyAutoridad UVA Orcid
    Año del Documento
    2019
    Editorial
    MDPI
    Descripción
    Producción Científica
    Documento Fuente
    Proceedings, 2019, vol. 16, n. 1, 22
    Zusammenfassung
    Ventilated façades are among the existing measures to reduce the energy demand in buildings. The combination of this passive heating and cooling strategy with photovoltaics (PV) can drive new buildings towards the current European targets for near or even net zero-energy buildings (nZEB). The present work aims at studying the PV integrated ventilated façade of the nZEB known as “LUCIA” at the University of Valladolid, Spain. First, the transmissivity of the PV façade is measured. Then, the monitoring of the available solar radiation is presented together with the air-dry bulb temperatures indoors, outdoors and inside the ventilated façade. The experimental results permit the validation of a mathematical model that describes the behaviour of the ventilated façade in its current operating modes. The results show that dampers should be closed during winter to let the façade act as a further insulation for outdoor temperatures below 18.4 C to improve energy efficiency. Indoor air recirculation would be helpful during 10% of the winter period.
    Palabras Clave
    Photovoltaics
    Energía fotovoltaica
    ISSN
    2504-3900
    Revisión por pares
    SI
    DOI
    10.3390/proceedings2019016022
    Patrocinador
    Junta de Castilla y Leon - Fondo Europeo de Desarrollo Regional (project VA272P18)
    VIPSKILLS (project 2016-1-PL01-KA203-026152 Erasmus +)
    Version del Editor
    https://www.mdpi.com/2504-3900/16/1/22
    Propietario de los Derechos
    © 2019 The Authors
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/55879
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Aparece en las colecciones
    • DEP46 - Artículos de revista [100]
    Zur Langanzeige
    Dateien zu dieser Ressource
    Nombre:
    Improved-performance-PV.pdf
    Tamaño:
    788.8Kb
    Formato:
    Adobe PDF
    Thumbnail
    Öffnen
    Atribución 4.0 InternacionalSolange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Atribución 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10