• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UVaDOCCommunitiesBy Issue DateAuthorsSubjectsTitles

    My Account

    Login

    Statistics

    View Usage Statistics

    Share

    View Item 
    •   UVaDOC Home
    • SCIENTIFIC PRODUCTION
    • Departamentos
    • Dpto. Teoría de la Señal y Comunicaciones e Ingeniería Telemática
    • DEP71 - Artículos de revista
    • View Item
    •   UVaDOC Home
    • SCIENTIFIC PRODUCTION
    • Departamentos
    • Dpto. Teoría de la Señal y Comunicaciones e Ingeniería Telemática
    • DEP71 - Artículos de revista
    • View Item
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Export

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/59894

    Título
    Design and validation of a scalable, reconfigurable and low-cost structural health monitoring system
    Autor
    Villacorta Calvo, Juan JoséAutoridad UVA Orcid
    Val Puente, Lara delAutoridad UVA Orcid
    Martínez López, Roberto DiegoAutoridad UVA
    Balmori Roiz, José AntonioAutoridad UVA Orcid
    Magdaleno González, ÁlvaroAutoridad UVA Orcid
    López Rodríguez, GamalielAutoridad UVA Orcid
    Izquierdo Fuente, AlbertoAutoridad UVA Orcid
    Lorenzana Ibán, AntolínAutoridad UVA Orcid
    Basterra Otero, Luis AlfonsoAutoridad UVA Orcid
    Año del Documento
    2021
    Editorial
    MDPI
    Descripción
    Producción Científica
    Documento Fuente
    Sensors, 2021, Vol. 21, Nº. 2, 648
    Abstract
    This paper presents the design, development and testing of a low-cost Structural Health Monitoring (SHM) system based on MEMS (Micro Electro-Mechanical Systems) triaxial accelerometers. A new control system composed by a myRIO platform, managed by specific LabVIEW software, has been developed. The LabVIEW software also computes the frequency response functions for the subsequent modal analysis. The proposed SHM system was validated by comparing the data measured by this set-up with a conventional SHM system based on piezoelectric accelerometers. After carrying out some validation tests, a high correlation can be appreciated in the behavior of both systems, being possible to conclude that the proposed system is sufficiently accurate and sensitive for operative purposes, apart from being significantly more affordable than the traditional one.
    Materias (normalizadas)
    Structural health monitoring
    Microelectromechanical systems
    Microelectronics
    Microelectrónica
    Accelerometers
    Acelerómetros
    Nondestructive testing
    ISSN
    1424-8220
    Revisión por pares
    SI
    DOI
    10.3390/s21020648
    Patrocinador
    Junta de Castilla y León y Fondo Europeo de Desarrollo Regional (FEDER) - (grant VA095P17 and VA228P20)
    Version del Editor
    https://www.mdpi.com/1424-8220/21/2/648
    Propietario de los Derechos
    © 2021 The authors
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/59894
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Collections
    • DEP71 - Artículos de revista [358]
    Show full item record
    Files in this item
    Nombre:
    Design-and-Validation.pdf
    Tamaño:
    3.708Mb
    Formato:
    Adobe PDF
    Thumbnail
    FilesOpen
    Atribución 4.0 InternacionalExcept where otherwise noted, this item's license is described as Atribución 4.0 Internacional

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10