Show simple item record

dc.contributor.advisorMateos Villán, David es
dc.contributor.advisorGonzález Fernández, Danieles
dc.contributor.authorBastante Chichón, Miriam
dc.contributor.editorUniversidad de Valladolid. Facultad de Ciencias es
dc.date.accessioned2023-11-28T14:45:04Z
dc.date.available2023-11-28T14:45:04Z
dc.date.issued2022
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/63285
dc.description.abstractEl principal objetivo de este TFG es determinar las diferencias entre diferentes fotómetros (CIMEL, PFR y SP1A) situados en un mismo lugar, Ny-Ålesund. También, se determinan las diferencias entre dos fotómetros, CIMEL, situados en dos localizaciones cercanas, Ny-Ålesund y Hornsund. Se presentan en este trabajo comparaciones entre las diferentes estimaciones del espesor óptico del aerosol (AOD) y del exponente de Ångström (AE) tomadas de la base de datos del proyecto europeo Rehearsol en Ny-Ålesund y Hornsund. Se ha tomado como fotómetro de referencia el CIMEL situado en Ny-Ålesund. En el periodo de 2017 al 2018, se observa una sobreestimación del AOD del PFR y una subestimación del AOD del SP1A respecto al de referencia. En cambio, en el caso del AE se obtienen valores en ambos fotómetros, PFR y SP1A, superiores a los del CIMEL. Las comparaciones entre el CIMEL situado en Ny-Ålesund y el situado en Hornsund determinan que, en el periodo de estudio (2017-2020), los valores de AOD son mayores en Hornsund mientras que los valores de AE son menores. Lo que indica que no se miden en ambas localizaciones las mismas masas de aire. Las tendencias observadas tanto anuales como mensuales desde el 2002 al 2020, no son estadísticamente significativas. Aunque, se aprecia una ligera disminución de los valores del AOD en la mayor parte de los instrumentos y longitudes de onda analizados. Se puede concluir que existe una buena concordancia entre los datos obtenidos en los diferentes fotómetros analizados.es
dc.description.abstractThe main goal of this study is to analyse the differences between the measurements using different collocated photometers (CIMEL, PFR y SP1A) in Ny-Ålesund base. In addition, the differences between two CIMEL photometers situated at two nearby locations, Ny-Ålesund and Hornsund, are determined. A comparison between different estimations of the Aerosol Optical Depth (AOD) and the Ångström Exponent (AE) are shown in this study. Both have been taken from the european proyect Rehearsol’s data base in Ny-Ålesund and Hornsund. The CIMEL from Ny-Ålesund has been used as a reference photometer. In 2017-2018 PFR measured an overestimation in AOD over the reference, meanwhile an underestimation was observed by SP1A. But three instruments present an uncertainty inside the AOD limits established by the World Meteorology Organization. The AE was overestimated in both PFR and SP1A instead. In addition, it has been verified that the exact same air masses were not measured in Ny-Ålesund and Hornsund due to the comparison between the different CIMELs. In the study period, 2017-2020, AOD values are higher in Hornsund while AE values are lower. The trends observed both annual and monthly from 2002 to 2020 are statistically negligible. Even though a slight decrease in AOD is shown in most of the analysed instruments and wavelengths.es
dc.description.sponsorshipDepartamento de Física Teórica, Atómica y Ópticaes
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subject.classificationAODes
dc.subject.classificationSvalbardes
dc.subject.classificationCIMELes
dc.titleObservación del aerosol ártico mediante distintas técnicas de medidaes
dc.typeinfo:eu-repo/semantics/bachelorThesises
dc.description.degreeGrado en Físicaes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record