• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo UVaDOCComunidadesPor fecha de publicaciónAutoresMateriasTítulos

    Mi cuenta

    Acceder

    Estadísticas

    Ver Estadísticas de uso

    Compartir

    Ver ítem 
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Física de la Materia Condensada, Cristalografía y Mineralogía
    • DEP32 - Comunicaciones a congresos, conferencias, etc.
    • Ver ítem
    •   UVaDOC Principal
    • PRODUCCIÓN CIENTÍFICA
    • Departamentos
    • Dpto. Física de la Materia Condensada, Cristalografía y Mineralogía
    • DEP32 - Comunicaciones a congresos, conferencias, etc.
    • Ver ítem
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/71078

    Título
    Daylight electroluminescence inspection of PV panels on-site vs. Traditional EL inspection with Silicon cameras
    Autor
    Carpintero, Luis Alberto
    Congreso
    EUPVSEC 2024
    Año del Documento
    2024
    Resumen
    This paper presents a comparative study of electroluminescence (EL) imaging of silicon photovoltaic (PV) panels in three currently operating PV plants. EL images were acquired using two methods: in a darkroom with a silicon sensor reflex camera after dismantling the panels; and during daylight without dismantling the panels using an InGaAs sensor camera (dEL). The results demonstrate that dEL can detect the same important defects in the PV panels while being not only less costly in terms of time and money but also able to prevent the production of new defects resulting from disassembly, transportation and reassembly of the modules. This way, dEL provides a more efficient and reliable procedure for quality control and maintenance.
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/71078
    Tipo de versión
    info:eu-repo/semantics/submittedVersion
    Derechos
    openAccess
    Aparece en las colecciones