Mostrar el registro sencillo del ítem

dc.contributor.authorFernández Bueno, Iván 
dc.contributor.authorUsategui Martín, Ricardo 
dc.contributor.authorPastor Jimeno, José Carlos 
dc.contributor.authorAndrés-Iglesias, Cristina
dc.date.accessioned2024-11-14T12:01:49Z
dc.date.available2024-11-14T12:01:49Z
dc.date.issued2021
dc.identifier.citationTranslational Vision Science & Technology 2021;10:17es
dc.identifier.issn2164-2591es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/71461
dc.descriptionProducción Científicaes
dc.description.abstractPurpose: High frequency of cataracts and the requirements of new European Union regulations for medical devices require the availability of preclinical models to adequatelyevaluateanteriorlens capsuledyes beforetheir usein patients.Herein, we describeanexvivomethodtoquantifiablyevaluatethemacroscopicandmicroscopic stainingeffectivenessofanteriorlenscapsuledyesusingporcineeyes. Methods: Commercially available trypan blue–based products or physiological saline solution(negativecontrol)wasinjectedintoporcineeyes.Anteriorpoleandlens(after extraction) were macroscopically photographed, and the images were quantitatively analyzed. Lenses were histologically processed, and the staining intensity microscopi- callywassemiquantified. Results: Macroscopic evaluation of the anterior pole revealed bluish staining of the anteriorcapsule;however,thiscoloringcannotbemacroscopicallydiscernedafterlens extraction.Quantitativeimageanalysesshowedsignificant(P < 0.01)stainingofthelens capsule compared to the negative control, but not significant (P > 0.05) between the productstested.Quantitativeanalysisofdyingonlensimagescouldnotbeperformed. Microscopicsemiquantificationofthecapsulestainingintensityallowsustoappreciate differencesbetweenproducts. Conclusions: The described method is a quick and useful tool for macroscopic evalu- ation by surgeons to choose an anterior capsule staining for use during everyday surgeries, and a more specific microscopic evaluation also allows us to determine the effectivenessandusefulnessoftheseproducts. Translational Relevance: This method satisfies preclinical effectiveness evaluations requiredbyEuropeanUnionregulationsandcomplementsthesafetyandtoxicityevalu- ationsthatnewproductsmustguaranteebeforetheyenterthemarketandareusedin clinicalpractice.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleEx-Vivo Method to Quantifiably Evaluate the Staining Effectiveness of Anterior Lens Capsule Dyeses
dc.typeinfo:eu-repo/semantics/articlees
dc.identifier.doi10.1167/tvst.10.14.17es
dc.identifier.publicationfirstpage17es
dc.identifier.publicationissue14es
dc.identifier.publicationtitleTranslational Vision Science & Technologyes
dc.identifier.publicationvolume10es
dc.peerreviewedSIes
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem