Mostrar el registro sencillo del ítem

dc.contributor.authorMartínez Plaza, Elena 
dc.contributor.authorLópez De La Rosa, Alberto 
dc.contributor.authorPapadatou, Eleni
dc.contributor.authorHabib, Nabil E.
dc.contributor.authorÁguila Carrasco, Antonio J. del
dc.contributor.authorLópez Miguel, Alberto 
dc.contributor.authorMaldonado López, Miguel José 
dc.contributor.authorBuckhurst, Phillip J.
dc.date.accessioned2025-01-25T15:51:51Z
dc.date.available2025-01-25T15:51:51Z
dc.date.issued2023-06
dc.identifier.citationMartínez-Plaza E, López-de la Rosa A, Papadatou E, Habib NE, Del Águila-Carrasco AJ, López-Miguel A, Maldonado MJ, Buckhurst PJ. Influence of decentration and tilt of Tecnis ZCB00 on visual acuity and higher order aberrations. Eye (Lond). 2023 Jun;37(8):1640-1645es
dc.identifier.issn0950-222Xes
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/74388
dc.descriptionProducción Científicaes
dc.description.abstractBackground/objectives: To determine the influence of decentration and tilt of a pseudophakic aspheric intraocular lens (IOL) on visual acuity (VA) and higher-order aberrations (HOAs), and to analyze the agreement between pupil center/axis and iridocorneal angles center/axis when assessing IOL decentration and tilt. Subjects/methods: A prospective interventional case series study including thirty-three patients undergoing Tecnis ZCB00 (Abbott Medical Optics) implantation. IOL decentration and tilt with respect to two reference systems (pupil and iridocorneal angles centers/axes), in cartesian (X,Y) and polar (radius/tilt, polar angle/azimuth) coordinates, were assessed with optical coherence tomography. VA and internal and ocular HOAs were evaluated. Multiple linear regression models and intraclass correlation coefficient (ICC) were computed. Results: IOL decentration only showed a significant effect on internal HOAs for [Formula: see text] (R2 = 0.20, P = 0.04). IOL decentration with respect to the pupil center showed a significant effect on ocular [Formula: see text] (R2 = 0.18, P = 0.05), [Formula: see text] (R2 = 0.36, P = 0.001) and [Formula: see text] (R2 = 0.24, P = 0.02); and with respect to the center of iridocorneal angles, on ocular [Formula: see text] (R2 = 0.21, P = 0.03), [Formula: see text] (R2 = 0.32, P = 0.003), primary coma (R2 = 0.41, P < 0.001), and coma-like (R2 = 0.40, P = 0.001). Poor agreement between both reference systems was found for IOL decentration measurements (ICC ≤ 0.41), except for the polar angle coordinate (ICC = 0.83). Tilt measurements showed good agreement (ICC ≥ 0.75). Conclusions: Tecnis ZCB00 decentration and tilt values after uneventful implantation appear not to have influence on VA, and their effect on HOAs are not high enough to clinically affect quality of vision. Pupil and iridocorneal angles used as reference systems may be interchangeable for IOL tilt measurements, but not for decentration.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherSpringer Naturees
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses
dc.titleInfluence of decentration and tilt of Tecnis ZCB00 on visual acuity and higher order aberrationses
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holderThe Author(s), under exclusive licence to The Royal College of Ophthalmologists 2022es
dc.identifier.doi10.1038/s41433-022-02211-2es
dc.relation.publisherversionhttps://www.nature.com/articles/s41433-022-02211-2
dc.identifier.publicationfirstpage1640es
dc.identifier.publicationissue8es
dc.identifier.publicationlastpage1645es
dc.identifier.publicationtitleEyees
dc.identifier.publicationvolume37es
dc.peerreviewedSIes
dc.description.projectJunta de Castilla y León and European Social Fund (EDU/ 1100/2017).es
dc.identifier.essn1476-5454es
dc.type.hasVersioninfo:eu-repo/semantics/submittedVersiones


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem