dc.description.abstractLa presente investigación evalúa el impacto de la mejora de los acristalamientos de fachada en edificios del siglo XX con valor patrimonial, con el objetivo de analizar su influencia en el confort térmico interior y la demanda energética. Se busca verificar el cumplimiento de las exigencias de la sección HE1 del Documento Básico de Ahorro de Energía (CTE DB-HE 2022), contrastando los resultados obtenidos con los criterios de confort establecidos en el RITE. El estudio se desarrolla a partir del caso de un aula docente con orientación suroeste, ubicada en la sede del Paseo del Cauce de la Escuela de Ingenierías Industriales de la Universidad de Valladolid. Mediante el uso de herramientas de simulación energética como CYPE MEP y CYPETHERM HE Plus, se comparan distintas configuraciones de huecos, clasificadas como condición inicial, variante recomendada y variante óptima. El análisis integra criterios normativos, antecedentes energéticos y térmicos del mismo edificio, así como las características técnicas de los componentes de la ventana, tales como el acristalamiento y los marcos. Los resultados demuestran que es posible mejorar de forma significativa el comportamiento térmico del edificio mediante soluciones pasivas compatibles con su valor patrimonial, reduciendo la demanda energética y optimizando el confort interior sin comprometer su integridad arquitectónica. La investigación concluye con una serie de recomendaciones técnicas aplicables a intervenciones similares en el patrimonio arquitectónico del siglo XX.es
dc.description.abstractThis research evaluates the impact of improving façade glazing in 20th-century buildings of heritage value, with the aim of analyzing its influence on interior thermal comfort and energy demand. The aim is to verify compliance with the requirements of Section HE1 of the Basic Energy Saving Document (CTE DBHE 2022), comparing the results obtained with the comfort criteria established in the RITE (Spanish Institute of Building and Construction Technology) The study focuses on the case of a southwest-facing classroom located at the Paseo del Cauce campus of the School of Industrial Engineering of the University of Valladolid. Using energy simulation tools such as CYPE MEP and CYPETHERM HE Plus, different opening configurations are compared, classified as initial conditions, recommended variants, and optimal variants. The analysis integrates regulatory criteria, energy and thermal data from the building itself, as well as the technical characteristics of window components, such as glazing and frames. The results demonstrate that it is possible to significantly improve the building's thermal performance through passive solutions compatible with its heritage value, reducing energy demand and optimizing interior comfort without compromising its architectural integrity. The research concludes with a series of technical recommendations applicable to similar interventions in 20th-century architectural heritage.es
dc.description.sponsorshipDepartamento de Urbanismo y Representación de la Arquitecturaes
dc.format.mimetypeapplication/pdfes
dc.language.isospaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleImpacto de la rehabilitación energética en el patrimonio arquitectónico del siglo XX. Estudio de un aula de la escuela técnica superior de ingenierías industriales sede paseo del Cauce.es
dc.typeinfo:eu-repo/semantics/doctoralThesises
dc.description.degreeMáster en Investigación e Innovación en Arquitectura. Intervención en el Patrimonio, Rehabilitación y Regeneraciónes