Mostrar el registro sencillo del ítem

dc.contributor.authorGutiérrez Tobal, Gonzalo César
dc.contributor.authorHornero Sánchez, Roberto 
dc.contributor.authorÁlvarez, Daniel
dc.contributor.authorMarcos, José Víctor
dc.contributor.authorCampo Matias, Félix del 
dc.date.accessioned2024-02-07T09:24:56Z
dc.date.available2024-02-07T09:24:56Z
dc.date.issued2012
dc.identifier.citationPhysiological Measurement, Julio, 2012, vol. 33, n 7, pp. 1261-1275es
dc.identifier.issn0967-3334es
dc.identifier.urihttps://uvadoc.uva.es/handle/10324/65879
dc.descriptionProducción Científicaes
dc.description.abstractThis paper focuses on the analysis of single-channel airflow (AF) signal to help in sleep apnoea–hypopnoea syndrome (SAHS) diagnosis. The respiratory rate variability (RRV) series is derived from AF by measuring time between consecutive breathings. A set of statistical, spectral and nonlinear features are extracted from both signals. Then, the forward stepwise logistic regression (FSLR) procedure is used in order to perform feature selection and classification. Three logistic regression (LR) models are obtained by applying FSLR to features from AF, RRV and both signals simultaneously. The diagnostic performance of single features and LR models is assessed and compared in terms of sensitivity, specificity, accuracy and area under the receiver-operating characteristics curve (AROC). The highest accuracy (82.43%) and AROC (0.903) are reached by the LR model derived from the combination of AF and RRV features. This result suggests that AF and RRV provide useful information to detect SAHS.es
dc.format.mimetypeapplication/pdfes
dc.language.isoenges
dc.publisherIOPes
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccesses
dc.titleLinear and nonlinear analysis of airflow recordings to help in sleep apnoea–hypopnoea syndrome diagnosises
dc.typeinfo:eu-repo/semantics/articlees
dc.rights.holderIOPes
dc.identifier.doi10.1088/0967-3334/33/7/1261es
dc.relation.publisherversionhttps://iopscience.iop.org/es
dc.identifier.publicationfirstpage1261es
dc.identifier.publicationissue7es
dc.identifier.publicationlastpage1275es
dc.identifier.publicationtitlePhysiological Measurementes
dc.identifier.publicationvolume33es
dc.peerreviewedSIes
dc.description.projectThis work has been partially supported by the project VA111A11-2 from Consejería de Educación de la Junta de Castilla y León, by the Proyectos Cero on Ageing from Fundación General CSIC, by Consejería de Educación de la Junta de Castilla y León (Orden EDU/1204/2010) and by the European Social Foundes
dc.identifier.essn1361-6579es
dc.type.hasVersioninfo:eu-repo/semantics/acceptedVersiones


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem