Mostrar el registro sencillo del ítem
dc.contributor.author | Gutierrez Tobal, Gonzalo César | |
dc.contributor.author | Hornero Sánchez, Roberto | |
dc.contributor.author | Álvarez González, Daniel | |
dc.contributor.author | Marcos Martín, José Víctor | |
dc.contributor.author | Campo Matias, Félix del | |
dc.date.accessioned | 2024-02-07T09:24:56Z | |
dc.date.available | 2024-02-07T09:24:56Z | |
dc.date.issued | 2012 | |
dc.identifier.citation | Physiological Measurement, Julio, 2012, vol. 33, n 7, pp. 1261-1275 | es |
dc.identifier.issn | 0967-3334 | es |
dc.identifier.uri | https://uvadoc.uva.es/handle/10324/65879 | |
dc.description | Producción Científica | es |
dc.description.abstract | This paper focuses on the analysis of single-channel airflow (AF) signal to help in sleep apnoea–hypopnoea syndrome (SAHS) diagnosis. The respiratory rate variability (RRV) series is derived from AF by measuring time between consecutive breathings. A set of statistical, spectral and nonlinear features are extracted from both signals. Then, the forward stepwise logistic regression (FSLR) procedure is used in order to perform feature selection and classification. Three logistic regression (LR) models are obtained by applying FSLR to features from AF, RRV and both signals simultaneously. The diagnostic performance of single features and LR models is assessed and compared in terms of sensitivity, specificity, accuracy and area under the receiver-operating characteristics curve (AROC). The highest accuracy (82.43%) and AROC (0.903) are reached by the LR model derived from the combination of AF and RRV features. This result suggests that AF and RRV provide useful information to detect SAHS. | es |
dc.format.mimetype | application/pdf | es |
dc.language.iso | eng | es |
dc.publisher | IOP | es |
dc.rights.accessRights | info:eu-repo/semantics/restrictedAccess | es |
dc.title | Linear and nonlinear analysis of airflow recordings to help in sleep apnoea–hypopnoea syndrome diagnosis | es |
dc.type | info:eu-repo/semantics/article | es |
dc.rights.holder | IOP | es |
dc.identifier.doi | 10.1088/0967-3334/33/7/1261 | es |
dc.relation.publisherversion | https://iopscience.iop.org/ | es |
dc.identifier.publicationfirstpage | 1261 | es |
dc.identifier.publicationissue | 7 | es |
dc.identifier.publicationlastpage | 1275 | es |
dc.identifier.publicationtitle | Physiological Measurement | es |
dc.identifier.publicationvolume | 33 | es |
dc.peerreviewed | SI | es |
dc.description.project | This work has been partially supported by the project VA111A11-2 from Consejería de Educación de la Junta de Castilla y León, by the Proyectos Cero on Ageing from Fundación General CSIC, by Consejería de Educación de la Junta de Castilla y León (Orden EDU/1204/2010) and by the European Social Found | es |
dc.identifier.essn | 1361-6579 | es |
dc.type.hasVersion | info:eu-repo/semantics/acceptedVersion | es |