• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Parcourir

    Tout UVaDOCCommunautésPar date de publicationAuteursSujetsTitres

    Mon compte

    Ouvrir une session

    Statistiques

    Statistiques d'usage de visualisation

    Compartir

    Voir le document 
    •   Accueil de UVaDOC
    • PUBLICATIONS SCIENTIFIQUES
    • Departamentos
    • Dpto. Teoría de la Señal y Comunicaciones e Ingeniería Telemática
    • DEP71 - Artículos de revista
    • Voir le document
    •   Accueil de UVaDOC
    • PUBLICATIONS SCIENTIFIQUES
    • Departamentos
    • Dpto. Teoría de la Señal y Comunicaciones e Ingeniería Telemática
    • DEP71 - Artículos de revista
    • Voir le document
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/65884

    Título
    Frequency-domain active contours solution to evaluate intima–media thickness of the common carotid artery
    Autor
    Bastida Jumilla, María Consuelo
    Menchon Lara, Rosa MaríaAutoridad UVA
    Morales Sánchez, Juan
    Verdú Monedero, Rafael
    Larrey Ruiz, Jorge
    Sancho Gómez, José Luis
    Año del Documento
    2015
    Documento Fuente
    Biomedical Signal Processing and Control, Volume 16, Pages 68-79, 2015
    Résumé
    The intima–media thickness (IMT) of the common carotid artery (CCA) is being used as a reliable and early detector of atherosclerosis. Atherosclerosis may be unnoticed fo years before triggering severe illnesses such as stroke, embolisms or ischemia. Hence, the use of IMT leads to an early atherosclerosis diagnosis that can prevent more serious cardiovascular diseases. Usually, IMT is manually extracted from ultrasound images, which is a non-invasive technique, but unfortunately its measurement is prone to error. This paper addresses a fully automatic method to segment the artery layers of the CCA over ultrasound images. Unlike other methods, the segmentation is not restricted to IMT, the artery diameter can be extracted too, which can help to determine cardiovascular risk together with IMT. The proposed technique is based on a frequency-domain implementation of active contours, which are computationally faster than the original space-formulation, while providing soft final contours. Working with three different probes over a range of spatial resolutions from 0.029mm/pixel to 0.081mm/pixel, the method presents an IMT error of only 13.8±31.9μm (in mean±standard deviation) when tested on an database containing 46 images. The automatic results were compared to the average of 2 manual observations performed by 2 observers (4 observations) over each image in our database.
    ISSN
    1746-8094
    Revisión por pares
    SI
    DOI
    10.1016/j.bspc.2014.08.012
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/65884
    Tipo de versión
    info:eu-repo/semantics/submittedVersion
    Derechos
    restrictedAccess
    Aparece en las colecciones
    • DEP71 - Artículos de revista [358]
    Afficher la notice complète
    Fichier(s) constituant ce document
    Nombre:
    blind_articleBSPC_v4.pdf
    Tamaño:
    1.873Mo
    Formato:
    Adobe PDF
    Thumbnail
    Voir/Ouvrir

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10