• español
  • English
  • français
  • Deutsch
  • português (Brasil)
  • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Stöbern

    Gesamter BestandBereicheErscheinungsdatumAutorenSchlagwortenTiteln

    Mein Benutzerkonto

    Einloggen

    Statistik

    Benutzungsstatistik

    Compartir

    Dokumentanzeige 
    •   UVaDOC Startseite
    • WISSENSCHAFTLICHE ARBEITEN
    • Departamentos
    • Dpto. Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia
    • DEP11 - Artículos de revista
    • Dokumentanzeige
    •   UVaDOC Startseite
    • WISSENSCHAFTLICHE ARBEITEN
    • Departamentos
    • Dpto. Cirugía, Oftalmología, Otorrinolaringología y Fisioterapia
    • DEP11 - Artículos de revista
    • Dokumentanzeige
    • español
    • English
    • français
    • Deutsch
    • português (Brasil)
    • italiano

    Exportar

    RISMendeleyRefworksZotero
    • edm
    • marc
    • xoai
    • qdc
    • ore
    • ese
    • dim
    • uketd_dc
    • oai_dc
    • etdms
    • rdf
    • mods
    • mets
    • didl
    • premis

    Citas

    Por favor, use este identificador para citar o enlazar este ítem:https://uvadoc.uva.es/handle/10324/82133

    Título
    Correlations Between Disability Score, Optical Coherence Tomography and Microperimetry in Patients with Multiple Sclerosis
    Autor
    Guantay, Carla
    Mena-García, Laura
    Tola-Arribas, Miguel
    Garea García-Malvar, María José
    Yugueros Fernández, María
    Mayo-Iscar, Agustín
    Pastor, José
    Año del Documento
    2024
    Editorial
    DovePress. Taylor & Francis
    Descripción
    Producción Científica
    Documento Fuente
    Carla D Guantay, Laura Mena-García, Miguel Ángel Tola-Arribas, María José Garea García-Malvar, María Isabel Yugueros Fernández, Agustín Mayo-Iscar & José Carlos Pastor (2024) Correlations Between Disability Score, Optical Coherence Tomography and Microperimetry in Patients with Multiple Sclerosis, Eye and Brain, , 89-100, DOI: 10.2147/ EB.S469182
    Zusammenfassung
    Purpose: To characterize ocular motility disturbances through Microperimetry (MP) in patients with Multiple Sclerosis (MS) trying to detect those capable of influencing the disability to improve the accuracy of assessing visual impact in EDSS scale. MP results were compare with some structural parameters obtained by OCT. Patients and methods: Cross-sectional analytical and correlational case-control study approved by Ethical Committee. A total of 82 eyes (41 patients) and 30 healthy eyes (15 subjects) were enrolled after informed consent. All participants underwent ophthalmological evaluation with MP and OCT. Variables included MS disease duration, Expanded Disability Status Scale (EDSS) score; in OCT: central macular thickness (CMT), ganglion cell-inner plexiform layer thickness (GCIPL), and peripapillary retinal nerve fiber layer thickness (pRNFL); and in MP: test duration, reaction time, average macular threshold (AT), and 4 fixation stability indexes (P1, P2, BCEA63, BCEA95). Results: MS group showed a significant decrease in GCIPL (p < 0.001) and pRNFL thickness (p < 0.001) compared to the control group. Furthermore, patients demonstrated a longer examination (p < 0.001) and reaction (p < 0.001) times, reduced AT (p < 0.001), more unstable fixation indexes (P1 p <0.004, P2 p = 0.018, BCEA63 p = 0.005 and BCEA95 p = 0.007), measured by MP. In addition, patients with a history of ON (n=16) demonstrated longer examination times in MP (p = 0.049) compared to MS patients without ON, but they were not correlations with OCT measurements, EDSS score correlated with the CMT (p = 0.023, r = -0.25), MP duration (p = 0.043, r = 0.22), and fixation indexes (P1 p = 0.049, r = -0.22, BCEA63 p = 0.041, r = 0.23, BCEA95 p = 0.049, r = 0.22). Conclusion: Our study emphasizes the complementary utility of MP and OCT in assessing MS patients. Additionally, it highlights that using MP for objective measurements of oculomotor dysfunction could improves accuracy in disability assessment on the EDSS scale.
    Palabras Clave
    ocular movement anomalies, expanded disability status scale, neurodegenerative diseases, fixation instability, retinal sensitivity
    ISSN
    11792744
    Revisión por pares
    SI
    DOI
    10.2147/EB.S469182
    Patrocinador
    This study was supported by the grants from the Gerencia Regional de Salud de Castilla y León (grant no. GRS 2498/A/ 22). Agustín Mayo-Iscar research was partially supported by grant PID2021-128314NB-I00 funded by MCIN/AEI/ 10.13039/501100011033/FEDER.
    Version del Editor
    https://www.tandfonline.com/doi/metrics/10.2147/EB.S469182?scroll=top#metrics-summary
    Idioma
    eng
    URI
    https://uvadoc.uva.es/handle/10324/82133
    Tipo de versión
    info:eu-repo/semantics/publishedVersion
    Derechos
    openAccess
    Aparece en las colecciones
    • DEP11 - Artículos de revista [282]
    Zur Langanzeige
    Dateien zu dieser Ressource
    Nombre:
    Correlations Between Disability Score Optical Coherence Tomography and Microperimetry in Patients with Multiple Sclerosis.pdf
    Tamaño:
    802.2Kb
    Formato:
    Adobe PDF
    Thumbnail
    Öffnen
    Attribution-NonCommercial-NoDerivs 3.0 UnportedSolange nicht anders angezeigt, wird die Lizenz wie folgt beschrieben: Attribution-NonCommercial-NoDerivs 3.0 Unported

    Universidad de Valladolid

    Powered by MIT's. DSpace software, Version 5.10